日期:2014-05-16  浏览次数:20649 次

[求助]mail服务器当掉,大家帮帮忙,谢谢谢谢
问题描述
Reboot服务器后,出现如下提示:
大家帮帮忙,我该如何解决这个问题
谢谢,谢谢(下文我是手动敲上去的,若有错误单词,请见谅)
/dev/hda1/   |==============         ……%
……
……
IO_support   =   3   (32-bit   w/sycn)
ummaskirq   =   1   (on)
using_dma   =   1   (on)
Activating   swap...Adding   979924K   swap   on   /dev/hda7
Priovity   :   -l   extents:laeross   :   979924k   done.
Check   root   file   system   with   errors,check   forced.
dev/hda/:   contains   a   file   system   with   errors,check   forced.
dev/hda/:Inodes   that   were   part   of     a   corrupted   orphan   linked   list   fuond.
/dev/hda/:   UNEXPFCTED   INCONSISTENCY;RUN   fack   MANUALLY
(i,e,without   -a   or   -p   options)
fsck   died   with   exit   status   4  
failed   (Code   4)   (显示为红色,提问者注释)  

An   automatic   file   system   check   (fsck)   of   the   root   filesystem   failed.
A   manual   fsck   must   be   performed,then   the   system   restarted.
The   fsck   should   be   performed   in   a   maintenance   mode   with   the   root   filesystem
mounted   in   read-only   mode.
The   root   filesystem   is   currently   mounted   in   read-only   mode.
A   maintenance   shell   with   now   be   started.
After   proforming   system   maintenance,press   CONTROL-D
to   terminater   the   maintenance   shell   and   restart   the   system.
Give   root   password   for   maintenance
(or   Control-D   to   continue):


------解决方案--------------------
文件系统损坏,用光盘进去,然后fsck -y /dev/hda1到hdaN,N的取值看你的分区情况